Modify glass length |
This variable from the dialog box SYSCAD-Variable / Attachment-Details / Glass can be used to set glass length in the sections. On default this variable is set to 50 mm. This value specifies the length, that is used to draw the glass in automatically generated sections or with manual glazing. The value can be modified according to your demands. It should not exceed half the true size of the glass pane. It would cause an error message with generating sections saying: 'interrupted sectional view is negative'. With setting the glass length to '0', the glass is drawn in true length in the section generation. However, when glazing profiles the glass is drawn with 50 mm length.
|